A PHP Error was encountered

Severity: Notice

Message: Only variable references should be returned by reference

Filename: core/Common.php

Line Number: 257

Citra Wahana Sekar Buana | LB-1000
Citra Wahana Sekar Buana

Product

LB-1000

Specification
Battery Types: 1.2V, 2V, 4V, 6V, 8V & 12V
single or multi-cell jars
Charge/Discharge Current: Charge Current per Cell:
1.2V: 1 – 30A
2V: 1 – 100A
4V: 1 – 30A
6V: 1 – 30A
8V: 1 – 30A
12V: 1 – 30A
Discharge Current per Cell:
1.2V: 1 – 25A(1)
2V: 1 – 100A
6V: 1 – 30A
4V: 1 – 30A
8V: 1 – 30A
12V: 1 – 30A
Total Charging/Discharging Voltage: 1.2V: 1.08 – 1.41V (Discharge); 1.08 – 1.44V (Charge)
2V: 1.8 – 2.35V (Discharge); 1.8 – 2.4V (Charge)
4V: 3.6 – 4.7V (Discharge); 3.6 – 4.8V (Charge)
6V: 5.4 – 7.05V(Discharge); 5.4 – 7.2V (Charge)
8V: 7.2 – 9.4V (Discharge); 7.2 – 9.6V (Charge)
12V: 10.8 – 14.1V (Discharge); 10.8 – 14.4V (Charge)
Accuracy: Charge/Discharge Current: 1.0%
Total Charging/Discharging Voltage: 0.25%
Resolution: Charge/Discharge Current: 1.0 A
Total Charging/Discharging Voltage: 0.1 V
Display: 124 x 64 pixel color LCD
Operating Environment: 0 – 50°C (32 – 122°F)
5 – 90% Relative Humidity
Power Requirements: AC 110/60Hz or AC
230/50HZ(2)
Dimensions: 40 x 30 x 20 cm (15.7 x 11.8 x 7.9 in)
Weight: 22 lbs (10 kg)
Description

The Eagle Eye LB-1000 is a complete solution for daily battery maintenance. It offers three complete solutions: battery charger system, battery discharger and battery activator. All of these functions in one unit make the LB-1000 an important tool for any battery maintenance program.

 

The battery charger system, battery discharger, and battery activator options can be used individually or comprehensively. When the options are used comprehensively, lag-out battery will experience low-volt constant current charging and discharging of single or multi-cell batteries (1 – 100A). By activating the disabled active material of the battery electrode plate, it amends the battery malfunction caused by chemical failure and boosts the capacity of an old battery. Activation curve and certain parameters (Ex. voltage and resistance) will display on the screen as activation ends. The LB-1000 can only amend weak batteries caused by chemical malfunction, and not of a physical failure such as a short-circuit.